VALVES

PRODUCT SELECTOR

SMART IN FLOW CONTROL

3222 N - electric - DIN

Globe valve

VALVE STYLE
Globe valve

USAGE

  • Low-pressure service
  • Throttling service

VERSION
DIN

MEDIUM TEMPERATURE
5 to 120 °C / 41 to 248 °F

SUPPLY
Electric

VALVE SIZE
DN 15

PRESSURE RATING
PN 16

LINING
without

Special features

  • Consisting of single-seated globe valve and actuator
  • Particularly suitable for local heat supply and large heating networks

Accessories

  • Type 2 NI Strainer

Options

  • Intermediate insulating piece
  • Threaded ends
  • Welding ends
  • Soldering ends

3222 N - electric - DIN can be combinated with the following actuations:

Special features:

  • Linear actuator for force-locking connection to valves
  • Optionally three-step version or with digital positioner
  • Motor switched off by torque-dependent limit contacts
  • Mechanical override
  • Travel indicator
Three-step version:
  • With synchronous motor and maintenance- free gear
Version with digital positioner:
  • Initialization by pressing a button
  • Direction of action reversed by slide switch
  • Momentary travel calculated from transit time
  • Operating status and errors indicated by LEDs
  • Adjustable stroking speed
  • Blockage detection and removal
  • Blocking protection
  • Adjustable input and output signal ranges
  • Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software

Special features:

  • Linear actuator with integrated digital controller
  • Force-locking connection to valves
  • Motor switched off by torque-dependent limit contacts
  • DHW heating control in instantaneous heating systems used in small to medium-sized buildings connected to a district heating or local heat supply network
  • Control using two different set points, e.g. DHW temperature and DHW temperature for thermal disinfection
  • Binary input to switch between set points
  • Function to maintain water temperature constant, preventing the heat exchanger from cooling down between tapping
  • Reversible direction of action
  • Limit value monitoring
  • Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software
  • Diagnosefunktion und Online-Verbindung zur Beobachtung über die Software TROVIS-VIEW
  • Operating status and errors indicated by LEDs
  • Travel indicator
  • Manual override

Special features:

  • Linear actuator with integrated digital controller
  • Force-locking connection to valves
  • Motor switched off by torque-dependent limit contacts
  • Control of small to medium-sized buildings
  • Outdoor-temperature-compensated control, fixed set point control, or fixed set point control with room temperature sensors
  • Return flow temperature limitation
  • Frost monitoring and automatic initiation of protective action
  • Automatic anti-blocking function prevents circulating pumps from seizing up
  • Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software
  • Diagnosefunktion und Online-Verbindung zur Beobachtung über die Software TROVIS-VIEW
  • Operating status and errors indicated by LEDs
  • Travel indicator
  • Manual override

Information

  • AB 02

    Flanges
    Connecting dimensions according to DIN EN 1092-1 and DIN 2501-1
    [EN][DE]
  • AB 05

    KV coefficient · Valve sizing
    [EN][DE]
  • T 5867

    Types 3222 N/5857, 3222 N/5757-3, 3222 N/5757-7 Electric Control Valves
    Single-seated Type 3222 N Globe Valve
    [EN][DE][RU]

Support

  • EB 5867

    Electric Control Valves
    Type 3222 N/5857, Type 3222 N/5757-3 and Type 3222 N/5757-7