3214 - electric - DIN
Globe valve
VALVE STYLE
Globe valve
USAGE
- Low-pressure service
- Throttling service
VERSION
DIN
MEDIUM TEMPERATURE
-10
to 220 °C /
14
to
428 °F
SUPPLY
Electric
VALVE SIZE
DN 15
to
DN 250
PRESSURE RATING
PN 16
to
PN 40
LINING
without
Special features
- Consisting of single-seated globe valve and actuator
- Balanced by a corrosion-resistant metal bellows
Accessories
- Type 2 NI Strainer
Options
- Flow divider in DN 65 and larger
3214 - electric - DIN can be combinated with the following actuations:
Special features:
- Linear actuator with integrated digital controller
- Suitable for 6 mm, 12 mm, or 15 mm rated travel
- Force-locking connection with 6 mm and 12 mm rated travel, form-fit connection with 15 mm rated travel
- Motor switched off by torque-dependent limit contacts
- Control using two different set points, e.g. DHW temperature and DHW temperature for thermal disinfection
- Manual setting possible at the set point potentiometer
- Function to maintain water temperature constant, preventing the heat exchanger from cooling down between tapping
- Pump output to control a circulation pump can alternatively be used as a fault alarm output
- Reversible direction of action
- Limit value monitoring
- Manual override
- Travel indicator
- Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software
Special features:
- Linear actuator with integrated digital controller
- Fail-safe action Actuator Stem Extends
- Suitable for 6 mm, 12 mm, or 15 mm rated travel
- Force-locking connection with 6 mm and 12 mm rated travel, form-fit connection with 15 mm rated travel
- Motor switched off by torque-dependent limit contacts
- Control using two different set points, e.g. DHW temperature and DHW temperature for thermal disinfection
- Manual setting possible at the set point potentiometer
- Function to maintain water temperature constant, preventing the heat exchanger from cooling down between tapping
- Pump output to control a circulation pump can alternatively be used as a fault alarm output
- Reversible direction of action
- Limit value monitoring
- Manual override
- Travel indicator
- Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software
Special features:
- Geeignet für SAM DISTRICT ENERGY
- Linear actuator with two integrated PID control modules
- Suitable for 6 mm, 12 mm, or 15 mm rated travel
- Force-locking connection with 6 mm and 12 mm rated travel, form-fit connection with 15 mm rated travel
- Motor switched off by torque-dependent limit contacts
- Ready-wired version with sensors and control line for easy installation
- Operating panel with display for set point adjustment and adjustable operating functions
- Fast start-up using system code numbers for fixed set point, follow-up, override and cascade control
- Manual override
- Travel indicator
Special features:
- Geeignet für SAM DISTRICT ENERGY
- Linear actuator with two integrated PID control modules
- Fail-safe action Actuator Stem Extends
- Suitable for 6 mm, 12 mm, or 15 mm rated travel
- Force-locking connection with 6 mm and 12 mm rated travel, form-fit connection with 15 mm rated travel
- Motor switched off by torque-dependent limit contacts
- Ready-wired version with sensors and control line for easy installation
- Operating panel with display for set point adjustment and adjustable operating functions
- Fast start-up using system code numbers for fixed set point, follow-up, override and cascade control
- Manual override
- Travel indicator
Special features:
- Linear actuator with 15 mm or 30 mm rated travel
- Compact design including electric or optionally mechanical override
- Optionally with fail-safe action (actuator stem retracts or extends) for version with electric override
Special features:
- SAM DIGITAL READY
- Linear actuator with 15 mm or 30 mm rated travel
- 15 mm version optionally with fail-safe action (actuator stem retracts or extends)
- Optionally three-step version or with digital positioner
- Optionally with integrated yoke or ring nut including the necessary stem connecting parts
- Synchronous motor with maintenance-free planetary gear
- Stepper motor with maintenance-free gearing
- All function settings performed using a rotary pushbutton on the actuator
- Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software
Information
T 5868
Types 3213/5857, 3213/5827, 3213/5757‑3, 3213/5757-7, 3213/5724-3, 3213/5724-8 and 3214/5827, 3214/3374, 3214/5724-3, 3214/5724-8 Electric Control Valves
Types 3213/2780 and 3214/2780 Pneumatic Control Valves
Single-seated Type 3213 Globe Valve, unbalanced
Single-seated Type 3214 Globe Valve, balanced
[EN][DE]T 5869
Single-seated Type 3213 Globe Valve, unbalanced
Single-seatedType 3214 Globe Valve, balancedElectric Control Valves with safety function, tested according to DIN EN 14597 Types 3213/5827-A, 3213/5725-3, 3213/5725-8 and 3214/5827-A, 3214/3374, 3214/5725-3, 3214/5725-8[EN][DE]T 5868-1
Types 3214/3374 and 3214/SAM Electric Control Valves
Type 3214 Globe Valve balanced by a diaphragm
[EN][DE]
Support
EB 5868/5869
Electric Control Valves
Types 3213/5857, 3213/5827-N, 3213/5757-3, 3213/5757-7, 3213/5724-3, 3213/5724-8 and 3214/5827-N, 3214/3374, 3214/5724-3, 3214/5724-8
With fail-safe action: Types 3213/5827-A, 3213/5827-E, 3213/5725-3, 3213/5725-8 and 3214/5725-3, 3214/5725-8, 3214/3374
Pneumatic Control Valves
Types 3213/2780 and 3214/2780
[EN][DE][PT]EB 5868-1
Types 3214/3374 and 3214/SAM Electric Control ValvesType 3214 Globe Valve balanced by a diaphragm[EN][DE]
Certificates
Only up-to-date documents are shown in the product selector. Check the documentation site for a list of all documents available.
Pin items on your list and contact us if you have any product-related questions.
Back to product selector