3214 - electric - DIN

Globe valve

VALVE STYLE
Globe valve

USAGE

  • Low-pressure service
  • Throttling service

VERSION
DIN

MEDIUM TEMPERATURE
-10 to 220 °C / 14 to 428 °F

SUPPLY
Electric

VALVE SIZE
DN 15 to DN 250

PRESSURE RATING
PN 16 to PN 40

LINING
without

Special features

  • Consisting of single-seated globe valve and actuator
  • Balanced by a corrosion-resistant metal bellows

Accessories

  • Type 2 NI Strainer

Options

  • Flow divider in DN 65 and larger

3214 - electric - DIN can be combinated with the following actuations:

Special features:

  • Linear actuator with integrated digital controller
  • Suitable for 6 mm, 12 mm, or 15 mm rated travel
  • Force-locking connection with 6 mm and 12 mm rated travel, form-fit connection with 15 mm rated travel
  • Motor switched off by torque-dependent limit contacts
  • Control using two different set points, e.g. DHW temperature and DHW temperature for thermal disinfection
  • Manual setting possible at the set point potentiometer
  • Function to maintain water temperature constant, preventing the heat exchanger from cooling down between tapping
  • Pump output to control a circulation pump can alternatively be used as a fault alarm output
  • Reversible direction of action
  • Limit value monitoring
  • Manual override
  • Travel indicator
  • Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software

Special features:

  • Linear actuator with integrated digital controller
  • Fail-safe action Actuator Stem Extends
  • Suitable for 6 mm, 12 mm, or 15 mm rated travel
  • Force-locking connection with 6 mm and 12 mm rated travel, form-fit connection with 15 mm rated travel
  • Motor switched off by torque-dependent limit contacts
  • Control using two different set points, e.g. DHW temperature and DHW temperature for thermal disinfection
  • Manual setting possible at the set point potentiometer
  • Function to maintain water temperature constant, preventing the heat exchanger from cooling down between tapping
  • Pump output to control a circulation pump can alternatively be used as a fault alarm output
  • Reversible direction of action
  • Limit value monitoring
  • Manual override
  • Travel indicator
  • Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software

Special features:

  • Geeignet für SAM DISTRICT ENERGY
  • Linear actuator with two integrated PID control modules
  • Suitable for 6 mm, 12 mm, or 15 mm rated travel
  • Force-locking connection with 6 mm and 12 mm rated travel, form-fit connection with 15 mm rated travel
  • Motor switched off by torque-dependent limit contacts
  • Ready-wired version with sensors and control line for easy installation
  • Operating panel with display for set point adjustment and adjustable operating functions
  • Fast start-up using system code numbers for fixed set point, follow-up, override and cascade control
  • Manual override
  • Travel indicator

Special features:

  • Geeignet für SAM DISTRICT ENERGY
  • Linear actuator with two integrated PID control modules
  • Fail-safe action Actuator Stem Extends
  • Suitable for 6 mm, 12 mm, or 15 mm rated travel
  • Force-locking connection with 6 mm and 12 mm rated travel, form-fit connection with 15 mm rated travel
  • Motor switched off by torque-dependent limit contacts
  • Ready-wired version with sensors and control line for easy installation
  • Operating panel with display for set point adjustment and adjustable operating functions
  • Fast start-up using system code numbers for fixed set point, follow-up, override and cascade control
  • Manual override
  • Travel indicator

Special features:

  • Linear actuator with 15 mm or 30 mm rated travel
  • Compact design including electric or optionally mechanical override
  • Optionally with fail-safe action (actuator stem retracts or extends) for version with electric override

Special features:

  • SAM DIGITAL READY
  • Linear actuator with 15 mm or 30 mm rated travel
  • 15 mm version optionally with fail-safe action (actuator stem retracts or extends)
  • Optionally three-step version or with digital positioner
  • Optionally with integrated yoke or ring nut including the necessary stem connecting parts
Three-step version:
  • Synchronous motor with maintenance-free planetary gear
Version with digital positioner:
  • Stepper motor with maintenance-free gearing
  • All function settings performed using a rotary pushbutton on the actuator
  • Configuration, parameterization, diagnostic function, and online connection for monitoring using the TROVIS-VIEW software

Information

  • WA 186

    Flyer: Compact and Powerful
    Low-maintenance valves balanced by a diaphragm for applications in heating and cooling water networks
    [EN][DE][FR]
  • AB 02

    Flanges
    Connecting dimensions according to DIN EN 1092-1 and DIN 2501-1
    [EN][DE]
  • AB 05

    KV coefficient · Valve sizing
    [EN][DE]
  • T 5868

    Types 3213/5857, 3213/5827, 3213/5757‑3, 3213/5757-7, 3213/5724-3, 3213/5724-8 and 3214/5827, 3214/3374, 3214/5724-3, 3214/5724-8 Electric Control Valves
    Types 3213/2780 and 3214/2780 Pneumatic Control Valves
    Single-seated Type 3213 Globe Valve, unbalanced
    Single-seated Type 3214 Globe Valve, balanced
    [EN][DE]
  • T 5869

    Single-seated Type 3213 Globe Valve, unbalanced
    Single-seatedType 3214 Globe Valve, balanced
    Electric Control Valves with safety function, tested according to DIN EN 14597 Types 3213/5827-A, 3213/5725-3, 3213/5725-8 and 3214/5827-A, 3214/3374, 3214/5725-3, 3214/5725-8
    [EN][DE]
  • T 5868-1

    Types 3214/3374 and 3214/SAM Electric Control Valves
    Type 3214 Globe Valve balanced by a diaphragm
    [EN][DE]

Support

  • EB 5868/5869

    Electric Control Valves
    Types 3213/5857, 3213/5827-N, 3213/5757-3, 3213/5757-7, 3213/5724-3, 3213/5724-8 and 3214/5827-N, 3214/3374, 3214/5724-3, 3214/5724-8
    With fail-safe action: Types 3213/5827-A, 3213/5827-E, 3213/5725-3, 3213/5725-8 and 3214/5725-3, 3214/5725-8, 3214/3374
    Pneumatic Control Valves
    Types 3213/2780 and 3214/2780
    [EN][DE][PT]
  • EB 5868-1

    Types 3214/3374 and 3214/SAM Electric Control Valves
    Type 3214 Globe Valve balanced by a diaphragm